Pancreatic Cancer Research

Clinical trialNATerminated

Reinforced Staple Line on Leak Rate in Distal Pancreatectomy

Effect of a Reinforced Staple Line on Leak Rate in Distal Pancreatectomy

Outcome
Stopped earlyThe 3rd interim analysis found superiority in the mesh reinforcement arm (Other)
Phase
NA
Status
Terminated
Study type
Interventional
Start
June 2007
Expected end
September 2011
Enrollment
112 participants
Sites
1
Primary outcomes
Clinically Significant Postoperative Pancreatic Leak at Any Time as Defined by the ISGPF Pancreatic Leak Grading System
Sponsor
Other
Results posted
2017-05-10
Last update
10 May 2017

These are registry fields. A trial card, with population, design, endpoints and result direction each tied to a quote, is not in the data yet.

Ask this document

Answers come only from this document’s own text, as highlighted quotes. If it doesn’t say, you are told so instead of given a guess.

Try

Source text

Brief summary public domain (ClinicalTrials.gov)

The investigators propose a randomized, controlled trial of stapled pancreatic transection versus mesh reinforced stapled pancreatic transection. For the duration of the study period, participating surgeons will utilize a standardized staple technique. Either a reabsorbable polytrimethylene carbonate mesh (SEAMGUARD®) or reabsorbable strips of bovine pericardium (PERI-STRIPS DRY®) will be used to reinforce the stapled pancreatic transection line in the test group. In order to have a uniform test method, the investigators will utilize a laparoscopic stapling device for both open and laparoscopic procedures and a uniform staple size (4.8mm).

Detailed description public domain (ClinicalTrials.gov)

Pancreatic leak remains a significant cause of morbidity and extra cost following distal pancreatectomy. Historically, previous attempts to reduce the leak rate have met with limited success. To examine this problem the investigators propose a randomized, controlled trial of stapled pancreatic transection versus mesh reinforced stapled pancreatic transection. For the duration of the study period, participating surgeons will utilize a standardized staple technique. Either a reabsorbable polytrimethylene carbonate mesh (SEAMGUARD®) or reabsorbable strips of bovine pericardium (PERI-STRIPS DRY®) will be used to reinforce the stapled pancreatic transection line in the test group. In order to have a uniform test method, the investigators will utilize a laparoscopic stapling device for both open and laparoscopic procedures and a uniform staple size (4.8mm). A drain will be placed in the left upper quadrant at the time of resection. Drainage of the pancreatic resection bed is widely accepted and remains our current standard of care.

Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)

Clinically Significant Postoperative Pancreatic Leak at Any Time as Defined by the ISGPF Pancreatic Leak Grading System [100 days or removal of drain]. Count Of Participants, Participants. Stapled Transection With Mesh Reinforcement (n=53): 1; Stapled Transection Without Mesh Reinforcement (n=45): 11.

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Occurrence of Any Fistula as Defined by the ISGPF Pancreatic Leak Grading System [100 days or removal of drain]. Count Of Participants, Participants. Stapled Transection With Mesh Reinforcement (n=53): 21; Stapled Transection Without Mesh Reinforcement (n=45): 26.

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Time to Drain Removal [100 days or removal of drain]. Median, days (95% Confidence Interval). Stapled Transection With Mesh Reinforcement (n=53): 9 (6 to 19); Stapled Transection Without Mesh Reinforcement (n=45): 17 (7 to 40).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Number of Non-pancreatic Adverse Events [100 days or removal of drain]. Number, non-pancreatic adverse events. Stapled Transection With Mesh Reinforcement (n=54): 21; Stapled Transection Without Mesh Reinforcement (n=46): 28.