Clinical trialObservationalCompleted
4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation
Individually Optimized Contrast-Enhancement 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation
- Outcome
- Results posted; single-arm, no comparison
- Phase
- Observational
- Status
- Completed
- Study type
- Observational
- Start
- July 2013
- Ended
- October 2014
- Enrollment
- 14 participants
- Sites
- 1
- Primary outcomes
- Individually Optimized Contrast-enhanced 4DCT for Radiotherapy Simulation
- Sponsor type
- Academic / other
- Results posted
- 27 March 2020
- Last update
- 27 March 2020
These fields come from the trial’s registry entry. A summary of its population, design, endpoints and results, each tied to a quote, has not been written for this trial yet.
Results
- Primary endpoint
- Results posted; single-arm, no comparisonAs posted on ClinicalTrials.gov ↗, registry record of 27 March 2020
- Primary outcome
- Individually Optimized Contrast-enhanced 4DCT for Radiotherapy SimulationAnatomic details: CE 3DCT: 4.1 (0.8), n = 10Anatomic details: 4DCT: 2.5 (0.6), n = 10Anatomic details: CE 4DCT: 3.6 (0.8), n = 10Motion artifacts: CE 3DCT: 3.9 (1.0), n = 10Motion artifacts: 4DCT: 3.4 (0.9), n = 10Motion artifacts: CE 4DCT: 3.7 (0.8), n = 10Beam hardening: CE 3DCT: 4.2 (0.8), n = 10Beam hardening: 4DCT: 3.3 (0.9), n = 10Beam hardening: CE 4DCT: 3.5 (0.8), n = 10Enhancement of pancreatic tissue and tumor: CE 3DCT: 3.2 (1.0), n = 10Enhancement of pancreatic tissue and tumor: 4DCT: 1.7 (0.9), n = 10Enhancement of pancreatic tissue and tumor: CE 4DCT: 3.3 (1.0), n = 10Values: mean units on a scale, Standard DeviationTime frame: 1 yearNo analysis posted for this outcome (outcome 1)
- Primary outcome
- Individually Optimized Contrast-enhanced 4DCT for Radiotherapy SimulationPancreas CT number (HU): CE 3DCT: 49.2 (12.3), n = 10Pancreas CT number (HU): 4DCT: 44.6 (15.9), n = 10Pancreas CT number (HU): CE 4DCT: 75.5 (21.2), n = 10Tumor CT number (HU): CE 3DCT: 53.0 (9.2), n = 10Tumor CT number (HU): 4DCT: 58.9 (14.3), n = 10Tumor CT number (HU): CE 4DCT: 76.3 (15.0), n = 10Tumor to pancreas contrast (HU): CE 3DCT: 15.5 (20.7), n = 10Tumor to pancreas contrast (HU): 4DCT: 9.2 (9.2), n = 10Tumor to pancreas contrast (HU): CE 4DCT: 16.7 (12.3), n = 10Noise (HU): CE 3DCT: 12.5 (3.9), n = 10Noise (HU): 4DCT: 19.4 (5.8), n = 10Noise (HU): CE 4DCT: 22.1 (5.7), n = 10Values: mean HU, Standard DeviationTime frame: 1 yearNo analysis posted for this outcome (outcome 2)
- Primary outcome
- Individually Optimized Contrast-enhanced 4DCT for Radiotherapy SimulationCE 3DCT: 1.4 (1.9), n = 104DCT: 0.6 (0.7), n = 10CE 4DCT: 0.8 (0.6), n = 10Values: mean contrast to noise ratio, Standard DeviationTime frame: 1 yearNo analysis posted for this outcome (outcome 3)
- Participants
- All Enrolled Patients: 14 started, 12 completed
- Serious adverse events
- All Enrolled Patients: 0 of 14Participants with at least one serious adverse event, of those at risk, as posted
Every value is copied from the trial’s results record at ClinicalTrials.gov. “Statistically significant” describes the posted test only: it does not say which group did better, and nothing here is read from a paper.
Ask this document
Answers come only from this document’s own text, as highlighted quotes. If it doesn’t say, you are told so instead of given a guess.
Try
Source text
Brief summary public domain (ClinicalTrials.gov)
The primary objective is to study the feasibility and efficacy of individually optimized CE 4D-CT for PDA in radiotherapy simulation.
Detailed description public domain (ClinicalTrials.gov)
Compared with current clinical practice, the individually optimized CE 4D-CT can potentially provide much improved tumor-to-parenchyma conspicuity of pancreatic adenocarcinoma. This will help the radiation oncologists or radiologists to contour the tumor with higher precision and confidence, and compute the tumor volume and tumor motion more accurately.
Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)
Individually Optimized Contrast-enhanced 4DCT for Radiotherapy Simulation [1 year]. Mean, units on a scale (Standard Deviation). Anatomic details: CE 3DCT (n=10): 4.1 (0.8); 4DCT (n=10): 2.5 (0.6); CE 4DCT (n=10): 3.6 (0.8). Motion artifacts: CE 3DCT (n=10): 3.9 (1.0); 4DCT (n=10): 3.4 (0.9); CE 4DCT (n=10): 3.7 (0.8). Beam hardening: CE 3DCT (n=10): 4.2 (0.8); 4DCT (n=10): 3.3 (0.9); CE 4DCT (n=10): 3.5 (0.8). Enhancement of pancreatic tissue and tumor: CE 3DCT (n=10): 3.2 (1.0); 4DCT (n=10): 1.7 (0.9); CE 4DCT (n=10): 3.3 (1.0).
Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)
Individually Optimized Contrast-enhanced 4DCT for Radiotherapy Simulation [1 year]. Mean, HU (Standard Deviation). Pancreas CT number (HU): CE 3DCT (n=10): 49.2 (12.3); 4DCT (n=10): 44.6 (15.9); CE 4DCT (n=10): 75.5 (21.2). Tumor CT number (HU): CE 3DCT (n=10): 53.0 (9.2); 4DCT (n=10): 58.9 (14.3); CE 4DCT (n=10): 76.3 (15.0). Tumor to pancreas contrast (HU): CE 3DCT (n=10): 15.5 (20.7); 4DCT (n=10): 9.2 (9.2); CE 4DCT (n=10): 16.7 (12.3). Noise (HU): CE 3DCT (n=10): 12.5 (3.9); 4DCT (n=10): 19.4 (5.8); CE 4DCT (n=10): 22.1 (5.7).
Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)
Individually Optimized Contrast-enhanced 4DCT for Radiotherapy Simulation [1 year]. Mean, contrast to noise ratio (Standard Deviation). CE 3DCT (n=10): 1.4 (1.9); 4DCT (n=10): 0.6 (0.7); CE 4DCT (n=10): 0.8 (0.6).