Clinical trialPhase 2Completed
Comparative Study of Sensitivity of Ga-DOTATOC PET vs Octreoscan SPECT + CT
Comparator Study of 68Ga-DOTATOC PET/CT With Octreoscan + High-resolution, Contrast-enhanced CT for Diagnosis and Staging in Neuroendocrine Tumors and Other Somatostatin Receptor Positive Tumors
- Outcome
- Results posted; single-arm, no comparison
- Phase
- Phase 2
- Status
- Completed
- Study type
- Interventional
- Start
- 1 April 2013
- Ended
- 26 December 2018
- Enrollment
- 68 participants
- Sites
- 1
- Primary outcomes
- Comparison of Conventional Imaging and Gallium Ga 68-edotreotide PET Using Concordance in Tumor Detection With Pathology; Compare Sensitivity of 68Ga-DOTATOC PET/CT With Octreoscan; Compare Specificity of 68Ga-DOTATOC PET/CT With Octreoscan
- Sponsor type
- Academic / other
- Results posted
- 22 September 2021
- Last update
- 22 September 2021
These fields come from the trial’s registry entry. A summary of its population, design, endpoints and results, each tied to a quote, has not been written for this trial yet.
Results
- Primary endpoint
- Results posted; single-arm, no comparisonAs posted on ClinicalTrials.gov ↗, registry record of 22 September 2021
- Primary outcome
- Comparison of Conventional Imaging and Gallium Ga 68-edotreotide PET Using Concordance in Tumor Detection With PathologySensitivity and Specificity for Ga-68-DOTATOC as Compared to Pathology / Total positive: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 28 of 34Sensitivity and Specificity for Ga-68-DOTATOC as Compared to Pathology / False position: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 0 of 34Sensitivity and Specificity for Ga-68-DOTATOC as Compared to Pathology / False negative: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 1 of 34Sensitivity and Specificity for Ga-68-DOTATOC as Compared to Pathology / Total negative: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 5 of 34Sensitivity and Specificity for OctreoScan as Compared to Pathology / Total positive: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 23 of 34Sensitivity and Specificity for OctreoScan as Compared to Pathology / False position: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 0 of 34Values: ParticipantsTime frame: Up to 6 months between the timing of the Octreoscan SPECT/CT plus high-resolution, contrast-enhanced CT and the time of the 68Ga-DOTATOC PET/CT (either imaging type may occur first)6 of 8 rows shownNo analysis posted for this outcome (outcome 1)
- Primary outcome
- Compare Sensitivity of 68Ga-DOTATOC PET/CT With OctreoscanSensitivity of Ga-68-DOTATOC: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 96.55, n = 34Sensitivity of OctreoScan: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 79.31, n = 34Sensitivity of Conventional Imaging (CI): Diagnostic (Gallium Ga 68-edotreotide PET/CT): 82.24, n = 34Values: percentage of sensitivityTime frame: Up to 6 monthsNo analysis posted for this outcome (outcome 2)
- Primary outcome
- Compare Specificity of 68Ga-DOTATOC PET/CT With OctreoscanSpecificity of 68Ga-DOTATOC: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 100, n = 34Specificity of Octreoscan: Diagnostic (Gallium Ga 68-edotreotide PET/CT): 100, n = 34Specificity of Conventional Imaging (CI): Diagnostic (Gallium Ga 68-edotreotide PET/CT): 47.82, n = 34Values: percentage of specificityTime frame: 6 monthsNo analysis posted for this outcome (outcome 3)
- Participants
- Diagnostic (Gallium Ga 68-edotreotide PET/CT): 68 started, 64 completed
- Serious adverse events
- Diagnostic (Gallium Ga 68-edotreotide PET/CT): 0 of 68Participants with at least one serious adverse event, of those at risk, as posted
Every value is copied from the trial’s results record at ClinicalTrials.gov. “Statistically significant” describes the posted test only: it does not say which group did better, and nothing here is read from a paper.
Ask this document
Answers come only from this document’s own text, as highlighted quotes. If it doesn’t say, you are told so instead of given a guess.
Try
Source text
Brief summary public domain (ClinicalTrials.gov)
This clinical trial studies gallium Ga 68-edotreotide positron emission tomography (PET)/computed tomography (CT) compared with indium In 111 pentetreotide plus contrast-enhanced CT (or MRI) in diagnosing patients with neuroendocrine tumors and other somatostatin receptor positive tumors. Diagnostic procedures, such as gallium Ga 68-edotreotide PET/CT, may help find and diagnose somatostatin receptor positive neuroendocrine tumors. It is not yet known whether Ga 68-edotreotide PET/CT is as effective as indium In 111 pentetreotide plus contrast-enhanced CT (or MRI) in diagnosis and staging of patients with neuroendocrine tumors.
Detailed description public domain (ClinicalTrials.gov)
PRIMARY OBJECTIVES: I. To compare efficacy of \[68Ga\]-DOTA-tyr3-Octreotide (68Ga-DOTATOC) (gallium Ga 68-edotreotide) PET/CT with Octreoscan (indium In 111 pentetreotide) + high-resolution, contrast-enhanced CT for diagnosis and staging in patients with somatostatin receptor expressing tumors. OUTLINE: Patients receive gallium Ga 68-edotreotide intravenously (IV) and undergo PET/CT scan. Within 120 days, patients undergo standard indium In 111 pentetreotide contrast-enhanced CT or MRI scan. Patients may also undergo a second gallium Ga 68-edotreotide PET/CT scan within 3-6 months if the lesions of the first scan cannot be confirmed.
Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)
Comparison of Conventional Imaging and Gallium Ga 68-edotreotide PET Using Concordance in Tumor Detection With Pathology [Up to 6 months between the timing of the Octreoscan SPECT/CT plus high-resolution, contrast-enhanced CT and the time of the 68Ga-DOTATOC PET/CT (either imaging type may occur first)]. Count Of Participants, Participants. Sensitivity and Specificity for Ga-68-DOTATOC as Compared to Pathology / Total positive: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 28. Sensitivity and Specificity for Ga-68-DOTATOC as Compared to Pathology / False position: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 0. Sensitivity and Specificity for Ga-68-DOTATOC as Compared to Pathology / False negative: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 1. Sensitivity and Specificity for Ga-68-DOTATOC as Compared to Pathology / Total negative: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 5. Sensitivity and Specificity for OctreoScan as Compared to Pathology / Total positive: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 23. Sensitivity and Specificity for OctreoScan as Compared to Pathology / False position: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 0. Sensitivity and Specificity for OctreoScan as Compared to Pathology / False negative: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 6. Sensitivity and Specificity for OctreoScan as Compared to Pathology / Total negative: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 5.
Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)
Compare Sensitivity of 68Ga-DOTATOC PET/CT With Octreoscan [Up to 6 months]. Number, percentage of sensitivity. Sensitivity of Ga-68-DOTATOC: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 96.55. Sensitivity of OctreoScan: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 79.31. Sensitivity of Conventional Imaging (CI): Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 82.24.
Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)
Compare Specificity of 68Ga-DOTATOC PET/CT With Octreoscan [6 months]. Number, percentage of specificity. Specificity of 68Ga-DOTATOC: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 100. Specificity of Octreoscan: Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 100. Specificity of Conventional Imaging (CI): Diagnostic (Gallium Ga 68-edotreotide PET/CT) (n=34): 47.82.