Pancreatic Cancer Research

Clinical trialNo phase (not a drug trial)Completed

PET Enhanced CT Scan Performance in Cancer

PET / Enhanced CT Scan Performance in Cancer (Positron Emission Tomography Combined With Computed Tomography or Vascular Contrast CT Scan). COMBI TEP Study

Outcome
Results posted; single-arm, no comparison
Phase
No phase (not a drug trial)
Status
Completed
Study type
Interventional
Start
19 March 2010
Ended
15 July 2015
Enrollment
109 participants
Sites
0
Primary outcomes
Inter-observer (B1 and B2) Reproducibility of the PET-CT by Anatomical Regions
Sponsor type
Academic / other
Results posted
1 October 2019
Last update
18 November 2024

These fields come from the trial’s registry entry. A summary of its population, design, endpoints and results, each tied to a quote, has not been written for this trial yet.

Results

Primary endpoint
Results posted; single-arm, no comparisonAs posted on ClinicalTrials.gov ↗, registry record of 18 November 2024
Primary outcome
Inter-observer (B1 and B2) Reproducibility of the PET-CT by Anatomical RegionsThorax region: COMBI TEP : PET / Enhanced CT Scan: 0.7254 (0.6288 to 0.8220), n = 104Abdomen region: COMBI TEP : PET / Enhanced CT Scan: 0.7854 (0.6923 to 0.8784), n = 105Pelvis region: COMBI TEP : PET / Enhanced CT Scan: 0.7597 (0.6408 to 0.8787), n = 105Bone region: COMBI TEP : PET / Enhanced CT Scan: 0.6711 (0.4239 to 0.9183), n = 105Nervous system region: COMBI TEP : PET / Enhanced CT Scan: 1 (1 to 1), n = 105Values: Weighted kappa concordance coefficient, 95% Confidence IntervalTime frame: 1 yearNo analysis posted for this outcome (outcome 1)
Participants
COMBI TEP : PET / Enhanced CT Scan: 109 started, 105 completed
Serious adverse events
COMBI TEP : PET / Enhanced CT Scan: 0 of 109Participants with at least one serious adverse event, of those at risk, as posted
5 secondary outcomes
Inter-observer (B1 and B2) Reproducibility of the PET-CT at a Patient Level
COMBI TEP : PET / Enhanced CT Scan 0.6528 (0.5194 to 0.7863), n=104 [weighted Kappa coefficient, 95% Confidence Interval]
Inter-observer (N1 and B2) Reproducibility of the PET-CT by Anatomical Regions
Thorax region: COMBI TEP : PET / Enhanced CT Scan 0.8526 (0.7733 to 0.9319), n=103 [Weighted kappa concordance coefficient, 95% Confidence Interval] (first of 5 rows)
Inter-observer (N1 and B2) Reproducibility of the PET-CT at a Patient Level
COMBI TEP : PET / Enhanced CT Scan 0.7859 (0.6561 to 0.9157), n=103 [Weighted kappa concordance coefficient, 95% Confidence Interval]
Intra-observer Reproducibility of Injected CT Scan by Anatomical Regions
Thorax region: COMBI TEP : PET / Enhanced CT Scan 0.8141 (0.7129 to 0.9153), n=105 [Weighted Kappa concordance coefficient, 95% Confidence Interval] (first of 5 rows)
Intra-observer Reproducibility of Injected CT Scanat a Patient Level
COMBI TEP : PET / Enhanced CT Scan 0.7984 (0.6708 to 0.9260), n=105 [Weighted Kappa concordance coefficient, 95% Confidence Interval]

Every value is copied from the trial’s results record at ClinicalTrials.gov. “Statistically significant” describes the posted test only: it does not say which group did better, and nothing here is read from a paper.

Ask this document

Answers come only from this document’s own text, as highlighted quotes. If it doesn’t say, you are told so instead of given a guess.

Try

Source text

Brief summary public domain (ClinicalTrials.gov)

Hypothesis: The investigators would like to demonstrate that diagnosis performance of PET/CT scan without and with contrast agent (COMBI TEP), are equivalent or better than those of PET/ non enhanced CT scan (PET scan) associated with an enhanced CT scan. This research project is a pilot study given the few available data concerning this imaging exam reproducibility. This study is a prospective single center study.

Detailed description public domain (ClinicalTrials.gov)

Hypothesis: We would like to demonstrate that diagnosis performance of PET/CT scan without and with contrast agent (COMBI TEP), are equivalent or better than those of PET/ non enhanced CT scan (PET scan) associated with an enhanced CT scan. This research project is a pilot study given the few available data concerning this imaging exam reproducibility. This study allows us to assess the feasibility of such a large-scale study, but also to evaluate COMBI TEP performance. From these estimates, we can then consider a comparative study to evaluate the performance of COMBI PET. This study is a prospective single center study.

Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)

Inter-observer (B1 and B2) Reproducibility of the PET-CT by Anatomical Regions [1 year]. Number, Weighted kappa concordance coefficient (95% Confidence Interval). Thorax region: COMBI TEP : PET / Enhanced CT Scan (n=105): 0.7254 (0.6288 to 0.8220). Abdomen region: COMBI TEP : PET / Enhanced CT Scan (n=105): 0.7854 (0.6923 to 0.8784). Pelvis region: COMBI TEP : PET / Enhanced CT Scan (n=105): 0.7597 (0.6408 to 0.8787). Bone region: COMBI TEP : PET / Enhanced CT Scan (n=105): 0.6711 (0.4239 to 0.9183). Nervous system region: COMBI TEP : PET / Enhanced CT Scan (n=105): 1 (1 to 1).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Inter-observer (B1 and B2) Reproducibility of the PET-CT at a Patient Level [1 year]. Number, weighted Kappa coefficient (95% Confidence Interval). COMBI TEP : PET / Enhanced CT Scan (n=104): 0.6528 (0.5194 to 0.7863).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Inter-observer (N1 and B2) Reproducibility of the PET-CT by Anatomical Regions [1 year]. Number, Weighted kappa concordance coefficient (95% Confidence Interval). Thorax region: COMBI TEP : PET / Enhanced CT Scan (n=104): 0.8526 (0.7733 to 0.9319). Abdomen region: COMBI TEP : PET / Enhanced CT Scan (n=104): 0.8153 (0.7118 to 0.9187). Pelvis region: COMBI TEP : PET / Enhanced CT Scan (n=104): 0.7452 (0.6020 to 0.8885). Bone region: COMBI TEP : PET / Enhanced CT Scan (n=104): 0.8722 (0.7269 to 1.0000). Nervous system region: COMBI TEP : PET / Enhanced CT Scan (n=104): 1 (1 to 1).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Inter-observer (N1 and B2) Reproducibility of the PET-CT at a Patient Level [1 year]. Number, Weighted kappa concordance coefficient (95% Confidence Interval). COMBI TEP : PET / Enhanced CT Scan (n=103): 0.7859 (0.6561 to 0.9157).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Intra-observer Reproducibility of Injected CT Scan by Anatomical Regions [1 year]. Number, Weighted Kappa concordance coefficient (95% Confidence Interval). Thorax region: COMBI TEP : PET / Enhanced CT Scan (n=105): 0.8141 (0.7129 to 0.9153). Abdomen region: COMBI TEP : PET / Enhanced CT Scan (n=105): 0.7991 (0.6951 to 0.9032). Pelvis region: COMBI TEP : PET / Enhanced CT Scan (n=105): 0.7947 (0.6326 to 0.9568). Bone region: COMBI TEP : PET / Enhanced CT Scan (n=105): -0.0095 (-0.0227 to 0.0037). Nervous system region: COMBI TEP : PET / Enhanced CT Scan (n=105): 1 (1 to 1).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Intra-observer Reproducibility of Injected CT Scanat a Patient Level [1 year]. Number, Weighted Kappa concordance coefficient (95% Confidence Interval). COMBI TEP : PET / Enhanced CT Scan (n=105): 0.7984 (0.6708 to 0.9260).