Pancreatic Cancer Research

Clinical trialNo phase (not a drug trial)Completed

Covered vs Uncovered Metal Stents for Palliative Biliary Decompression in Inoperable Malignant Distal Bile Duct Obstruction

Randomized Controlled Trial Comparing Covered Versus Uncovered Metal Stents for Biliary Decompression in Inoperable Malignant Distal Bile Duct Obstruction

Outcome
Results posted; no analysis attached
Phase
No phase (not a drug trial)
Status
Completed
Study type
Interventional
Start
8 November 2017
Ended
1 December 2020
Enrollment
6 participants
Sites
2
Primary outcomes
Rate of Long-term Stent Failure
Sponsor type
Academic / other
Results posted
31 March 2022
Last update
31 March 2022

These fields come from the trial’s registry entry. A summary of its population, design, endpoints and results, each tied to a quote, has not been written for this trial yet.

Results

Primary endpoint
Results posted; no analysis attachedAs posted on ClinicalTrials.gov ↗, registry record of 31 March 2022
Primary outcome
Rate of Long-term Stent FailureU-SEMS Group: 0 of 3C-SEMS Group: 2 of 3Values: ParticipantsTime frame: One yearNo analysis posted for this outcome (outcome 1)
Participants
U-SEMS Group: 3 started, 3 completedC-SEMS Group: 3 started, 3 completed
Serious adverse events
U-SEMS Group: 0 of 3C-SEMS Group: 0 of 3Participants with at least one serious adverse event, of those at risk, as posted
1 secondary outcome
Rates of Adverse Stent-related or Intervention-related Outcomes
U-SEMS Group 0/3; C-SEMS Group 0/3 [Participants]

Every value is copied from the trial’s results record at ClinicalTrials.gov. “Statistically significant” describes the posted test only: it does not say which group did better, and nothing here is read from a paper.

Ask this document

Answers come only from this document’s own text, as highlighted quotes. If it doesn’t say, you are told so instead of given a guess.

Try

Source text

Brief summary public domain (ClinicalTrials.gov)

The purpose of this study is to compare the rate of long-term stent failure, defined as need for repeat biliary intervention following placement of C-SEMS vs U-SEMS for palliation of inoperable malignant distal bile duct obstruction.

Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)

Rate of Long-term Stent Failure [One year]. Count Of Participants, Participants. U-SEMS Group (n=3): 0; C-SEMS Group (n=3): 2.

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Rates of Adverse Stent-related or Intervention-related Outcomes [One Year]. Count Of Participants, Participants. U-SEMS Group (n=3): 0; C-SEMS Group (n=3): 0.