Pancreatic Cancer Research

Clinical trialNo phase (not a drug trial)Completed

Using Electrical Bioimpedance Assessments to Estimate Perioperative Total Body Water and Postoperative Fluid Need

The Use of Multifrequency Bioimpedance Assessments as an Estimate of Perioperative Total Body Volume and Postoperative Fluid Resuscitation

Outcome
Results posted; single-arm, no comparison
Phase
No phase (not a drug trial)
Status
Completed
Study type
Interventional
Start
May 2012
Ended
July 2015
Enrollment
86 participants
Sites
1
Primary outcomes
Bioimpedance Assessment; Bioimpedance Assessment; Bioimpedance Assessment
Sponsor type
US federal agency
Results posted
28 August 2018
Last update
28 August 2018

These fields come from the trial’s registry entry. A summary of its population, design, endpoints and results, each tied to a quote, has not been written for this trial yet.

Results

Primary endpoint
Results posted; single-arm, no comparisonAs posted on ClinicalTrials.gov ↗, registry record of 28 August 2018
Primary outcome
Bioimpedance AssessmentBioimpedance Assessment: 0.53 (0.06), n = 45Values: mean ohms, Standard DeviationTime frame: preoperative measurementNo analysis posted for this outcome (outcome 1)
Primary outcome
Bioimpedance AssessmentBioimpedance Assessment: 0.57 (0.07), n = 45Values: mean ohms, Standard DeviationTime frame: 6 hours postoperative measurementNo analysis posted for this outcome (outcome 2)
Primary outcome
Bioimpedance AssessmentBioimpedance Assessment: 0.59 (0.24), n = 45Values: mean ohms, Standard DeviationTime frame: Average measurement, in ohms, taken daily for approximately 8-10 daysNo analysis posted for this outcome (outcome 3)
Participants
Bioimpedance Assessment: 86 started, 86 completed
Serious adverse events
Bioimpedance Assessment: 3 of 90Participants with at least one serious adverse event, of those at risk, as posted
9 secondary outcomes, the first 8 shown
Percent Extracellular Water Volume
Bioimpedance Assessment 0.89 (3.68), n=45 [mean percent of total water volume, Standard Deviation]
Percent Intracellular Water Volume
Bioimpedance Assessment 0.82 (1.54), n=45 [mean percent of total water volume, Standard Deviation]
Percent Extracellular Water Volume
Bioimpedance Assessment 0.32 (0.34), n=45 [mean percent of total water volume, Standard Deviation]
Percent Intracellular Water Volume
Bioimpedance Assessment 0.30 (0.04), n=45 [mean percent of total water volume, Standard Deviation]
Daily Fluid Balance (Intakes and Outputs)
Bioimpedance Assessment 1163.1 (1061.8), n=45 [mean mL, Standard Deviation]
Urine Output
Bioimpedance Assessment 406.7 (430.0), n=45 [mean mL, Standard Deviation]
Study Characteristics of Participants: Body Mass Index
Bioimpedance Assessment 27 (5), n=45 [mean kg/m^2, Standard Deviation]
American Society of Anaesthesiologists Physical Status Classification Scale
Bioimpedance Assessment 2.2 (0.56), n=45 [mean units on a scale, Standard Deviation]

Every value is copied from the trial’s results record at ClinicalTrials.gov. “Statistically significant” describes the posted test only: it does not say which group did better, and nothing here is read from a paper.

Ask this document

Answers come only from this document’s own text, as highlighted quotes. If it doesn’t say, you are told so instead of given a guess.

Try

Source text

Brief summary public domain (ClinicalTrials.gov)

Being able to accurately monitor patient bodily fluid levels during and after surgery is very important, as there are a number of complications that can arise if a patient's fluid levels become unbalanced, such as swelling within or pressure on various bodily organ systems. There are several different ways that physicians can monitor a patient's fluid balance during and after surgery, such as measuring the amount of urine output or the use of central venous catheters which measure the pressure in the veins entering the heart. Most of these techniques are invasive since they require tubes to be inserted into the body. A potential alternative would be to use a noninvasive technique such as electrical bioimpedance (BIA). Bioimpedance assessments work by using small electrical currents that can accurately predict both the water surrounding the outside of cells in the body, as well as the total amount of water in the entire body. Electrical bioimpedance assessments have been used to estimate patient swelling following surgery (edema), to measure the volume of blood the heart is pumping out, as well as to calculate body fat percentages. The goal of this study is to relate this technology to fluid shifts within the body that occur as a result of surgery, in particular, major intra-abdominal surgeries. By using bioimpedance during and after surgery, the investigators will compare the data collected with that calculated by using traditional measures of body fluid status, such as urine output and intraoperative blood loss. During the study, the bioimpedance monitors will not replace the standard bodily fluid monitors and will not interfere with their readings. Additionally, the electrical current produced by the bioimpedance monitors is too small for patients to feel and will not interfere with medical devices such as pacemakers.

Detailed description public domain (ClinicalTrials.gov)

Being able to accurately monitor patient bodily fluid levels during and after surgery is very important, as there are a number of complications that can arise if a patient's fluid levels become unbalanced, such as swelling within or pressure on various bodily organ systems. There are several different ways that physicians can monitor a patient's fluid balance during and after surgery, such as measuring the amount of urine output or the use of central venous catheters which measure the pressure in the veins entering the heart. Most of these techniques are invasive since they require tubes to be inserted into the body. A potential alternative would be to use a noninvasive technique such as electrical bioimpedance (BIA). Bioimpedance assessments work by using small electrical currents that can accurately predict both the water surrounding the outside of cells in the body, as well as the total amount of water in the entire body. Electrical bioimpedance assessments have been used to estimate patient swelling following surgery (edema), to measure the volume of blood the heart is pumping out, as well as to calculate body fat percentages. The goal of this study is to relate this technology to fluid shifts within the body that occur as a result of surgery, in particular, major intra-abdominal surgeries. By using bioimpedance during and after surgery, the investigators will compare the data collected with that calculated by using traditional measures of body fluid status, such as urine output and intraoperative blood loss. During the study, the bioimpedance monitors will not replace the standard bodily fluid monitors and will not interfere with their readings. Additionally, the electrical current produced by the bioimpedance monitors is too small for patients to feel and will not interfere with medical devices such as pacemakers.

Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)

Bioimpedance Assessment [preoperative measurement]. Mean, ohms (Standard Deviation). Bioimpedance Assessment (n=45): 0.53 (0.06).

Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)

Bioimpedance Assessment [6 hours postoperative measurement]. Mean, ohms (Standard Deviation). Bioimpedance Assessment (n=45): 0.57 (0.07).

Posted results (ClinicalTrials.gov registry) · primary outcome public domain (ClinicalTrials.gov)

Bioimpedance Assessment [Average measurement, in ohms, taken daily for approximately 8-10 days]. Mean, ohms (Standard Deviation). Bioimpedance Assessment (n=45): 0.59 (0.24).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Percent Extracellular Water Volume [preoperative measurement]. Mean, percent of total water volume (Standard Deviation). Bioimpedance Assessment (n=45): 0.89 (3.68).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Percent Intracellular Water Volume [6 hour postoperative measurement]. Mean, percent of total water volume (Standard Deviation). Bioimpedance Assessment (n=45): 0.82 (1.54).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Percent Extracellular Water Volume [6 hours postoperative measurement]. Mean, percent of total water volume (Standard Deviation). Bioimpedance Assessment (n=45): 0.32 (0.34).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Percent Intracellular Water Volume [Preoperative measurement]. Mean, percent of total water volume (Standard Deviation). Bioimpedance Assessment (n=45): 0.30 (0.04). Analysis, Bioimpedance Assessment: Mean Difference (Final Values) 0.53; p=<0.01; Chi-squared; superiority or other.

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Daily Fluid Balance (Intakes and Outputs) [Sum of intakes and outputs each day while inpatient, an average of 8 days]. Mean, mL (Standard Deviation). Bioimpedance Assessment (n=45): 1163.1 (1061.8).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Urine Output [preoperative measurement]. Mean, mL (Standard Deviation). Bioimpedance Assessment (n=45): 406.7 (430.0).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Study Characteristics of Participants: Body Mass Index [baseline measurement]. Mean, kg/m^2 (Standard Deviation). Bioimpedance Assessment (n=45): 27 (5).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

American Society of Anaesthesiologists Physical Status Classification Scale [preoperative]. Mean, units on a scale (Standard Deviation). Bioimpedance Assessment (n=45): 2.2 (0.56).

Posted results (ClinicalTrials.gov registry) · secondary outcome public domain (ClinicalTrials.gov)

Amount of Intraoperative Fluids [intraoperative measurement]. Mean, mL (Standard Deviation). Bioimpedance Assessment (n=45): 2472.6 (1147.0).