Clinical trialNo phase (not a drug trial)Completed
Study Comparing Pancreatic EUS-FNB With the 20-gauge Procore® and the 22-gauge Acquire® Needles
Multicentric Randomized Study Comparing the Histological and Molecular Material Quality Obtained by EUS-FNB of Pancreatic Mass With Two "Biopsic" Needles: the 20-gauge Procore® (Cook) and the 22-gauge Acquire® (Boston Scientific)
- Outcome
- Finished, no results posted
- Phase
- No phase (not a drug trial)
- Status
- Completed
- Study type
- Interventional
- Start
- 24 June 2018
- Ended
- 29 September 2019
- Enrollment
- 60 participants
- Sites
- 1
- Primary outcomes
- cumulative length of tissue core biopsies per needle pass
- Sponsor type
- Academic / other
- Results posted
- No
- Last update
- 1 October 2019
These fields come from the trial’s registry entry. A summary of its population, design, endpoints and results, each tied to a quote, has not been written for this trial yet.
Ask this document
Answers come only from this document’s own text, as highlighted quotes. If it doesn’t say, you are told so instead of given a guess.
Try
Source text
Brief summary public domain (ClinicalTrials.gov)
Multicenter randomized prospective study Criteria for inclusion: Patients admitted for EUS-FNB of a pancreatic mass Goals of the study: To compare the results of blinded punctures for suspicion of pancreatic tumor performed under endoscopic ultrasound in our center (Digestive Endoscopy Unit of the Digestive Pole Paris Bercy, PDPB), in terms of diagnosis and quality of histopathological material obtained with the help of 20G Procore, Cook and 22G Acquire needles, Boston Scientific. Main criterion: \- Biopsy core length of target tissue obtained by needle pass Number of patients: 60 patients Duration of the study: 1 year
Detailed description public domain (ClinicalTrials.gov)
Type of study: Multicenter randomized prospective study Criteria for inclusion: Patients admitted for ENDOSCOPIC ULTRASOUND FINE NEEDLE BIOPSY (EUS-FNB) of a pancreatic mass Exclusion criteria: Patients with an extra-pancreatic mass puncture Echendoscopic puncture contraindication or vascular interposition Goals of the study: To compare the results of blinded punctures for suspicion of pancreatic tumor performed under endoscopic ultrasound in our center (Digestive Endoscopy Unit of the Digestive Pole Paris Bercy, PDPB), in terms of diagnosis and quality of histopathological material obtained with the help of 20G Procore, Cook and 22G Acquire needles, Boston Scientific. Evaluation criteria : Main criterion: \- Biopsy core length of target tissue obtained by needle pass Secondary criteria * Presence of a core biopsy specimen * Sensitivity of EUS-FNB for the diagnosis of adenocarcinoma of the pancreas * False negative rate, Negative predictive value for the diagnosis of pancreatic adenocarcinoma * Computer Aided Morphometric Evaluation of the Tumor + Stroma Surface on All core biopsy specimens * Success rate of isolation of tumor cells and determination of transcriptomic signatures of pancreatic adenocarcinoma subtypes * Immediate complications of puncture * Variation in the quality of the puncture following the trans-duodenal or trans-gastric access route * Technical failure rate of puncture * Optional: inter and intra-observer evaluation of the anatomopathological criteria used (presence of a biopsy core, length of target tissue core per needle passage) Number of patients: 60 patients Duration of the study: 1 year
Papers 15
- Builds on itIntensive endoscopic resection for downstaging of polyp burden in patients with familial adenomatous polyposis (J-FAPP … DOI 10.1055/a-1945-9120↗
- Builds on itComparison of specimen quality among the standard suction, slow-pull, and wet suction techniques for EUS-FNA: A multice… DOI 10.4103/eus-d-21-00163↗
- Builds on itHybrid argon plasma coagulation-assisted endoscopic mucosal resection for large sessile colon polyps to reduce local re… DOI 10.1055/a-1677-3954↗
- Builds on itEfficacy and safety of cold versus hot snare polypectomy for small (5-9 mm) colorectal polyps: a multicenter randomized… DOI 10.1055/a-1327-8357↗
- Builds on itInterobserver reliability of methods to determine complete resection of adenomas in colonoscopy. DOI 10.1055/a-1331-4446↗
- Builds on itNovel ultrathin double-balloon endoscopy for the diagnosis of small-bowel diseases: a multicenter nonrandomized study. DOI 10.1055/a-1243-0226↗
- Builds on itImpact of mechanical simulator practice on clinical ERCP performance by novice surgical trainees: a randomized controll… DOI 10.1055/a-1217-6727↗
- Builds on itClinical impact of endoscopic ultrasound-guided through-the-needle microbiopsy in patients with pancreatic cysts. DOI 10.1055/a-1214-6043↗
- Builds on itA novel self-assembling peptide for hemostasis during endoscopic submucosal dissection: a randomized controlled trial. DOI 10.1055/a-1198-0558↗
- Builds on itEndoscopic submucosal dissection with additional radiotherapy in the treatment of T1a esophageal squamous cell cancer: … DOI 10.1055/a-1198-5232↗
- Builds on itContrast-enhanced harmonic versus standard endoscopic ultrasound-guided fine-needle aspiration in solid pancreatic lesi… DOI 10.1055/a-1193-4954↗
- Builds on itEducational nurse-led telephone intervention shortly before colonoscopy as a salvage strategy after previous bowel prep… DOI 10.1055/a-1178-9844↗
- Builds on itExpert assessment on volumetric laser endomicroscopy full scans in Barrett's esophagus patients with or without high gr… DOI 10.1055/a-1194-0397↗
- Builds on itEndoscopic full-thickness resection (eFTR) of colorectal lesions: results from the Dutch colorectal eFTR registry. DOI 10.1055/a-1176-1107↗
- Builds on it22G Acquire vs. 20G Procore needle for endoscopic ultrasound-guided biopsy of pancreatic masses: a randomized study com… DOI 10.1055/a-1160-5485↗